OperationsMid Level

Generator Technician

Performs maintenance, testing, and repair of diesel generators and emergency power systems including load bank testing

Experience

0+ years

Growth

Stable

Skills & Expertise

Required Skills

  • Electrical systems maintenance and troubleshooting
  • Generator set diagnostics and repair
  • NFPA 110 emergency power systems compliance
  • Preventive maintenance scheduling and documentation
  • UPS and backup power system knowledge
  • Electrical safety protocols and lockout/tagout procedures
  • Multifunction power monitoring systems

Preferred Skills

  • CDCP (Certified Data Center Professional) certification
  • EPMS (Electrical Power Management System) configuration
  • ServiceNow or Maximo maintenance management software
  • AutoCAD electrical system design
  • OSHA electrical safety certifications

A Day in the Life

What a typical workday looks like

My day starts promptly at 7:15 AM, arriving at the hyperscale data center facility in Phoenix. I log into the Maximo CMMS system, review overnight generator logs, and confirm no emergency calls occurred during the night shift. Today's priority is completing the quarterly load bank testing for Generator Sets A and B in the N+1 backup power array, ensuring 2N redundancy remains intact. By 10:30 AM, I'm responding to a preventative maintenance ticket for Generator Set C's fuel transfer pump, which showed slight vibration anomalies during last week's diagnostic scan. I coordinate with the Cummins field service representative to schedule potential component replacement, carefully documenting communication details and potential impact in our system. Meanwhile, I update the maintenance tracking spreadsheet and verify calibration records for our digital multimeters and thermal imaging equipment. During the scheduled maintenance window, I lead a two-person team conducting comprehensive load bank testing on Generators A and B. We methodically test each unit at 80% and 100% rated capacity, monitoring coolant temperatures, oil pressure, and electrical output using our Fluke power quality analyzer. The test validates system performance and identifies any potential degradation before a critical failure can occur. The afternoon involves troubleshooting an intermittent voltage regulation issue on Rack 14's backup power system. Using thermal imaging and advanced diagnostic tools, I trace potential circuit inconsistencies, ultimately identifying a minor capacitor degradation in the automatic transfer switch. I draft a detailed root cause analysis report and recommend a proactive component replacement during the next maintenance window. As my shift winds down, I prepare a comprehensive handover report for the evening technician, highlighting today's completed tasks, pending maintenance items, and any critical observations. I verify all systems are operating within specified parameters, update the maintenance log in our enterprise system, and conduct a final walkthrough of the generator room, ensuring everything is secure and operationally ready for the night shift.